System/Model
|
LP-1300 BSD
|
Chamber Size
|
Diameter
|
1300 mm
|
Height
|
1300 mm~1800 mm
|
Capacity
|
-
|
∮375x1,400 mm x6
|
Main Performance
|
Ultimate Pressure
|
Better than 10-6 Torr
|
Operation Pressure
|
From 1 atm to 5x10-5 Torr within 10 minutes (unloading)
|
View Windows
|
Set
|
1
|
Number of Filaments
|
Pcs
|
18~22
|
Pumping System
|
Rotary Pump
|
6,000~10,000 L/min
|
Booster Pump
|
1,500~3,000 M3/ hour
|
Diffusion Pump
|
3000~45,000 L/ sec
|
Holding Pump
|
300~600 L/min (Optional)
|
Vacuum Gauge
|
|
Pirani (760 ~10-3 Torr); Cold Cathode (10-3 ~ 10-6 Torr)
|
Control Box
|
Set
|
1
|
High Vacuum Valve
|
|
28~36 inch
|
Roughing Valve
|
|
6 inch
|
Foreline Valve
|
|
6 inch
|
Leak Valve
|
|
2 inch
|
Holding Valve (option)
|
|
1 inch
|
Evaporation Power Supply
|
|
30KW
|
System Operation
|
|
Automatic/ Manual
|
Cooling water flow rate
|
|
100 L/min
|
Cooling Tower
|
|
15 RT (Water Pressure: 4kg/ cm2; Pressure Drop: 2kg/ cm2)
|
Cooling Water
|
|
Inlet: 18℃; Outlet: 25℃; Standard: 20±1℃
|
Polycold
|
|
Option
|
PF Generator
|
|
Option
|
Air Compressor
|
|
3HP (Air Pressure: 6 ~ 8 kg/ cm2)
|
Electrical Control System
|
|
PLC
|
Total Power Requirement
|
|
75KW
|